ASHRAE Handbook 2016: HVAC Systems and Equipment (SI) by ASHRAE

By ASHRAE

Show description

Read or Download ASHRAE Handbook 2016: HVAC Systems and Equipment (SI) PDF

Best ventilation & air conditioning books

Directions in Strong Motion Instrumentation: Proceedings of the NATO SFP Workshop on Future Directions in Instrumentation for Strong Motion and Engineering ... IV: Earth and Environmental Sciences)

Robust flooring movement measuring and recording tools play a big position in mitigation of seismic danger. The powerful floor movement close to the resource of an earthquake describes the results that endanger our equipped atmosphere, and can also be the main specific clue in regards to the resource mechanism of the earthquake.

Radiant Heating and Cooling Handbook

Radiant Heating & Cooling Handbookthe first and merely specialist advisor to radiant heating and cooling procedure designPacked with instruments that make the paintings of HVAC structures designers, engineers, and technicians move extra easily and simply, this specialist guide good points the entire assist you have to create the latest and hottest and effective structures for commercial, advertisement, and home functions.

Architecture of Brazil: 1900-1990

Structure of Brazil: 1900-1990 examines the strategies that underpin smooth Brazilian structure less than numerous impacts and characterizes various understandings of modernity, obtrusive within the bankruptcy issues of this publication. hence, the writer doesn't provide total choice to specific architects nor works, except for a couple of particular works and designers, together with Warchavchik, Niemeyer, Lucio Costa, and Vilanova Artigas.

Industrial refrigeration handbook

Drawing from the easiest of the generally dispersed literature within the box and the authorÕs great specialist wisdom and adventure, here's todayÕs so much exhaustive, one-stop insurance of the basics, layout, set up, and operation of business refrigeration platforms. Detailing the adjustments because of the conversion from CFCs to non-ozone-depleting refrigerants and through the improvement of microprocessors and new secondary coolants, commercial Refrigeration instruction manual additionally examines multistage platforms; compressors, evaporators, and condensers; piping, vessels, valves and refrigerant controls; liquid recirculation; refrigeration load calculations; refrigeration and freezing of meals; and defense systems.

Extra resources for ASHRAE Handbook 2016: HVAC Systems and Equipment (SI)

Sample text

2 Direct-Expansion or Chilled-Water Cooling and Dehumidification Fig. 5 • Hot-water (fluid-filled) coils use temperature differences between the warm fluid and the cooler air. • Electric heat also uses the temperature difference between the heating coil and the air to exchange energy. • Direct or indirect gas- or oil-fired heat exchangers can also be used to add sensible heat to the airstream. The effect on the airstream for each of these processes is the same and is shown in Figure 5. For basic equations, refer to Chapter 1 of the 2013 ASHRAE Handbook—Fundamentals.

Many jurisdictions require monitoring, alarms, evacuation procedures, separating refrigeration and fuel-fired equipment, and high rates of purge ventilation. A proper operating environment for equipment and those maintaining it must also be provided. This may involve heating the space for freeze protection and/or cooling the space to prevent overheating motors and controls. , switchgear room, office space, generator room, pump room, machine shop). Where refrigeration equipment is installed, follow design requirements in ASHRAE Standard 15.

Some of these applications allow the designer to reduce air volume during unoccupied periods while still maintaining space pressure control. Allair systems are generally the only systems able to combine space pressure control with temperature, humidity, and/or air filtration control. Other Considerations All-air systems operate by maintaining a temperature differential between the supply air and the space. Any load that affects this differential and the associated airflow must be calculated and considered, including the following: • All fans (supply, return, and supplemental) add heat.

Download PDF sample

Rated 4.22 of 5 – based on 31 votes

Published by admin