Active and passive beam application design guide by -

By -

"This ebook presents instruments and information to layout, fee, and function energetic and passive beam platforms to accomplish a decided indoor weather. It additionally offers examples of energetic and passive beam calculations and selections"--

summary: "This e-book presents instruments and tips to layout, fee, and function lively and passive beam platforms to accomplish a decided indoor weather. It additionally offers examples of energetic and passive beam calculations and choices"

Show description

Read Online or Download Active and passive beam application design guide PDF

Best ventilation & air conditioning books

Directions in Strong Motion Instrumentation: Proceedings of the NATO SFP Workshop on Future Directions in Instrumentation for Strong Motion and Engineering ... IV: Earth and Environmental Sciences)

Robust floor movement measuring and recording tools play a big position in mitigation of seismic hazard. The robust floor movement close to the resource of an earthquake describes the consequences that endanger our outfitted setting, and can be the main particular clue in regards to the resource mechanism of the earthquake.

Radiant Heating and Cooling Handbook

Radiant Heating & Cooling Handbookthe first and in simple terms specialist advisor to radiant heating and cooling approach designPacked with instruments that make the paintings of HVAC structures designers, engineers, and technicians cross extra easily and simply, this professional guide gains the entire assist you have to create the most recent and preferred and effective structures for commercial, advertisement, and home purposes.

Architecture of Brazil: 1900-1990

Structure of Brazil: 1900-1990 examines the methods that underpin glossy Brazilian structure below numerous affects and characterizes diverse understandings of modernity, glaring within the bankruptcy subject matters of this ebook. therefore, the writer doesn't provide total choice to specific architects nor works, except for a couple of particular works and designers, together with Warchavchik, Niemeyer, Lucio Costa, and Vilanova Artigas.

Industrial refrigeration handbook

Drawing from the easiest of the generally dispersed literature within the box and the authorÕs great specialist wisdom and adventure, here's todayÕs such a lot exhaustive, one-stop assurance of the basics, layout, deploy, and operation of commercial refrigeration platforms. Detailing the alterations attributable to the conversion from CFCs to non-ozone-depleting refrigerants and by means of the advance of microprocessors and new secondary coolants, business Refrigeration guide additionally examines multistage structures; compressors, evaporators, and condensers; piping, vessels, valves and refrigerant controls; liquid recirculation; refrigeration load calculations; refrigeration and freezing of nutrition; and protection approaches.

Additional resources for Active and passive beam application design guide

Sample text

Determine the sensible cooling capacity of the primary air, S,p, Btu/h (kW). 2 × (DBIDA – DBSUP) SI 6. Determine the required sensible cooling capacity from the beam(s), S,b Btu/h (kW), which corresponds to the beam capacity, P, where P is the space-sensible cooling-load-cooling capacity of supply air volume 7. Determine the beam quantity, size, and water flow rate based on the sensible cooling requirement. 8. , as long as the room). In this case, the coil is sized according to the required cooling load.

Beam weights are typically 7 to 15 lb/ft (10 to 20 kg/m) dry. If beams are to be integrated into a suspended ceiling grid, the beams should be hung prior to the grid installation. The beam should be initially mounted 2 ½ to 3 in. (60 to 75 mm) above the plane of the finished ceiling. After installation of the ceiling grid, the beam is positioned horizontally, then carefully lowered into the ceiling module. A mounting method that allows roughly 3 in. (75 mm) of movement in all horizontal and vertical directions should be used to facilitate the final positioning in the ceiling system.

The beam should be initially mounted 2 ½ to 3 in. (60 to 75 mm) above the plane of the finished ceiling. After installation of the ceiling grid, the beam is positioned horizontally, then carefully lowered into the ceiling module. A mounting method that allows roughly 3 in. (75 mm) of movement in all horizontal and vertical directions should be used to facilitate the final positioning in the ceiling system. To allow beam movement and alignment, connections for the hydronic and air systems must be properly selected.